U7E eScore Target

Introduction to the U7E

The U7E is an electronic eScore target that registers shots using acoustic sensors. It is designed for supersonic ammunition and shooting distances of 100–200 metres. Its electronics and sensors are located at the bottom. This provides good protection when the target is installed correctly behind a protective wall or with protective plates.

U7E target features

  • 3 acoustic sensors, all located at the bottom of the target
  • Can be fitted with horizontal and vertical rubber bands
  • Manual rubber band rotation
  • Additional protective plates recommended
  • A wide range of target faces is available
  • The guide pins allow the target face to be changed quickly without readjusting the zero point.
  • Suitable for a range of supersonic calibres, from .223 to .338LM and larger

Technical specifications and dimensions

A

1160 mm

B

1300 mm

C

500 mm

D

300 mm

E

68 mm

F

36 mm

G

92 mm

H

155 mm

Temperature range −30 to +60 °C
Weight ~ 25 kg
Power consumption Approx. 4 W at 24 VDC
Calibers Supersonic projectiles

Exploded view and parts list

Exploded view

This shows the components of a typical eScore U target.



Parts list

Item Description
1 Target frame with hatches, cables, acoustic sensors, temperature sensors and target electronics
5 Front temperature shield (versions vary with the target face)
6 Rear temperature shield
7 Foam sheet with rubber (versions matched to the opening in the front temperature shield)
8 Target face (contact your W5 dealer for available options)
9 Guide pin nuts (8 pcs.)
10 Top cover
11 Measuring unit with target electronics, cables and three acoustic sensors


Dismantling


Maintenance and repairs

Maintenance intervals

The recommended rule of thumb rotation intervals are given in the following table:

Shooting distance Rotation interval
100 m After 500 rounds
200 m After 800 rounds
300 m After 1500 rounds

Note that the table above assumes normal full jacketed bullets and relatively good groupings. If groupings are large the intervals can be even longer.

Open the sections below for maintenance and repair instructions. More articles are available at docs.kongsbergtargets.com (opens in a new tab)

Sensor maintenance (when replacing the rubber band)

Maintaining sensors on eScore U targets

Equipment required

- Small brush

Procedure

Step 1 – Remove the target face and temperature shield

Remove the top cover

Unscrew the four front guide pin nuts

Remove the target face and temperature shield.

 

Remove

Step 2 - Open service panel

Open the service lid by releasing the two rubber straps on the front of the target service hatch. Lift the lid up to access electronics compartment.

Rubber straps keeps the service hatched closed. Right side is released

Lifting the service hatch reveals electronics and sensors. (U-target)

For H-targets the sensors are only placed in the bottom corners, not in the center.

Remove

Step 3 – Inspect the sensors

  • Inspect the sensors.
  • Lightly touch the sensors to ensure that they are correctly fastened.
  • Use a small brush to wipe away debris that may have landed on top of the sensors.


Sensor with debris

Remove

Step 4 – Close the service hatch

Close the service hatch and secure both rubber straps.

Ensure a tight seal around the hatch, both straps must be used.


Remove

Step 5 – Fit the temperature shield and target face

  • Install the temperature screen first by entering all four guide pins.
    Ensure that the rubber side of the foam faces forward.


  • Install the target face on the four alignment pins.



Remove

The target face may be orientation sensitive!

Ensure that the orientation is correct! - If center marks / engraving on the target face are visible, they shall face towards the shooter. If partnumber is engraved on the target face it shall be oriented so that the text is readable in the upright position


  • Fasten the four guide pin nuts by hand. There is no need to use excessive force while fastening these nuts.
  • Remember to re-attach the rain cover.
Remove

Protecting the U7E target

How to protect the U7E target against bullets and ricochets

The target's critical electronic components are located at the bottom, behind the service panel. Protect this area with a protective wall or plates to reduce maintenance costs and improve durability. Target stands with protective plates are available on request.

See YouTube video for recommendations on how to install the targets.

Protection from ricochets and shrapnel

Fragments from bullet catchers can cut or short-circuit cables. Route cables between targets, antennas, batteries and other equipment carefully to minimise this risk. Cover steel bullet catchers with rubber or another suitable energy-absorbing material to reduce escaping ricochets and fragments.