Updating Windows monitors (Rugged Monitor and other Windows tablets)
This guide explains how to manually update Rugged Monitors and other Windows tablets using a USB flash drive.
🔎 Why a manual update is required
When upgrading from a version earlier than 1.21.0 to version 1.21.0 or later, you need to perform a manual update once.
The previous code-signing certificate has expired and been replaced. This affects how Windows verifies the app and temporarily prevents automatic updates via eHub on Windows tablets.
After this manual update, automatic updates work normally again.
🔄 What the update does
- Uninstalls the previous version of the app
- Installs the new app version included in the update package
- Installs the root certificate needed to verify the app without an internet connection
- Updates references to the new app ID
- Updates shortcuts and startup scripts to point to the new app
🔧 What you need
- Download the update files (Contact W5 for the password)
- A USB flash drive containing the update files. Extract the files directly into the root folder of the drive.
- A monitor that is switched on. eScore-eMonitor can remain open.
📘 Updating the monitor
-
Insert the USB flash drive
Connect the drive to the monitor. File Explorer should open automatically. -
Run the update script
Double-clickLaunchCertificateAndAppIDFix.baton the USB drive. -
Allow changes to the device
Windows asks whether you want to allow the app to make changes to the device.
Select Yes to continue. -
The script performs the update
The script:
• Installs the required root certificate
• Updates the app IDs
• Corrects shortcuts and startup scripts -
Complete the update
When prompted to restart, you can:
• Press Y and then Enter to restart the monitor.
• Press N and then Enter, or close the window, to exit without restarting.
Tip: Double-tap near the prompt text to open the on-screen keyboard. -
After restarting
Remove the USB drive once the monitor has restarted. The monitor is now updated. - Register the monitors again under Settings → Connected device setup.
⚠️ Important
If an error occurs during the update:
• An error message.
• An alarm sounds if sound is enabled.
If the error message indicates that required software components are missing, you can install them using a separate script.
Open the /utils folder on the USB drive. It contains the file eMonitorInstallWithDependencies.bat.
The script installs the components the app needs to work.
Run this script in the same way as the update script: double-click the file, allow changes to the device and follow the on-screen instructions.