Maintaining sensors on eScore U targets
Equipment required
- Small brush
Procedure
Step 1 – Remove the target face and temperature shield
Remove the top cover

Unscrew the four front guide pin nuts

Remove the target face and temperature shield.
Step 2 - Open service panel
Open the service lid by releasing the two rubber straps on the front of the target service hatch. Lift the lid up to access electronics compartment.
Rubber straps keeps the service hatched closed. Right side is released
Lifting the service hatch reveals electronics and sensors. (U-target)
For H-targets the sensors are only placed in the bottom corners, not in the center.
Step 3 – Inspect the sensors
- Inspect the sensors.
- Lightly touch the sensors to ensure that they are correctly fastened.
- Use a small brush to wipe away debris that may have landed on top of the sensors.

Sensor with debris
Step 4 – Close the service hatch
Close the service hatch and secure both rubber straps.
Ensure a tight seal around the hatch, both straps must be used.

Step 5 – Fit the temperature shield and target face
- Install the temperature screen first by entering all four guide pins.
Ensure that the rubber side of the foam faces forward.

- Install the target face on the four alignment pins.

- Fasten the four guide pin nuts by hand. There is no need to use excessive force while fastening these nuts.
- Remember to re-attach the rain cover.