About the U4H target
The U4H is an electronic eScore target with acoustic sensors. It is designed for supersonic projectiles but also registers projectiles that have slowed below the speed of sound. It is developed for ranges of 200–600 metres or yards and is particularly suitable for long-range shooting.
The complete target line installation is shown in this video.

Features
- All sensors and electronics are at the bottom, making them easy to protect.
- Acoustic shot detection in a closed measuring chamber, unaffected by the weather.
- Several target faces are available.
- The guide pins allow quick target face replacement without adjusting the zero point.
Technical specifications and dimensions
A |
1822 mm |
|
B |
1826 mm |
|
C |
559 mm |
|
D |
305 mm |
|
E |
80 mm |
|
F |
40 mm |
|
G |
95 mm |
|
H |
164 mm |
The drawing below shows the target leg dimensions, using the underside of the service hatch as a reference.
| Temperature range | −30 to +60 °C |
| Weight | Approx. 76 kg |
| Power consumption | Approx. 4.4 W at 24 V DC |
| Calibres | Primarily designed for supersonic projectiles in calibres such as .223, .308, .30-06, 6.5 mm and 6 mm. The target also registers projectiles that have slowed below the speed of sound. |
Exploded view and parts list
The exploded view below shows the U4H target components.
| Item | Product name | W5 part no. |
| 1 | U4H target | 13020215 |
| 4 | Rubber skins (2 pcs.) | 97020426 |
| 8 |
Female I/O cable → Amphenol → M23 |
- 13020210 13020191 |
| 9 |
Male I/O cable → Amphenol → M23 |
- 13020209 13020190 |
| 10 |
Guide pins (6 pcs.) → unthreaded centre → headed, unthreaded (*Note1) |
- 97020850 97020845 |
| 11 | Small temperature shield | 13020112 |
| 12 | P00 temperature shield (rear) | 13020113 |
| 14 | Foam temperature shields (3 pcs.) | 13020288 |
| 15 |
FX target face → Ø36 inches, with hook-and-loop fasteners (*Note 2) → FC 1000 yards (printed) → USMC Threat Halo (printed) → USMC Dog Target (printed) Other versions on request. |
13020201 13020265 13020289 13020318 |
| 16 | Top cover | 97020351 |
| 17 | Guide pin nuts (normally 12 pcs.) | 97020729 |
| 20 | X-rubber | 13020218 |
Note1: This guide pin type can make fitting the X-rubber difficult on one side of the target. The other type is recommended.
Note2: This target face is used with the following printed aiming marks, attached with hook-and-loop fasteners:
| Description | W5 part no.: |
| 200-yard aiming mark, USA NRA SR | 13 02 0223 |
| 300-yard aiming mark, USA NRA SR-3 | 13 02 0224 |
| 600-yard aiming mark, USA NRA MR-1 | 13 02 0225 |
| 300-yard aiming mark, USA F-Class | 13 02 0262 |
| 500-yard aiming mark, USA F-Class | 13 02 0263 |
| 600-yard aiming mark, USA F-Class | 13 02 0264 |
Rubber skins and X-rubber
| The front and rear rubber skins form a soundproof measuring chamber. The X-rubber covers the opening in the front skin. This opening is 60 cm (24 inches) in diameter and reduces wear that can affect measurement accuracy. |
|
The X-rubber keeps the measuring chamber soundproof and simplifies maintenance. Hang it on the four mounting pins as shown. It must always sit tightly against the skin and cover the entire opening.
When coin-sized holes develop in the rear skin, an opening should also be cut there. The finished opening should be 60 cm (24 inches) in diameter. The skin stretches during installation, enlarging the marked opening. Mark a diameter of approximately 58 cm (23 inches) before cutting.
When fitting new X-rubber at the front, move the used X-rubber to the rear. It must sit tightly against the rear skin and cover the holes. The condition of the X-rubber and skin, particularly at the front, is important for measurement accuracy.
Dismantling
See the exploded view above.
The target must be partly dismantled for maintenance. Pull upwards to remove the top cover, which is attached with hook-and-loop fasteners. Other parts can be removed once the guide pin nuts are loosened.
U4H target maintenance
Replacing the X-rubber
Shooting wears the X-rubber. Replace it regularly to keep the measuring chamber soundproof. Intervals depend on the calibre, bullet type and shot grouping. The following intervals are a guide:
| Shooting distance | Replace after: |
| 200 yards / m | After 800 rounds |
| 300 yards / m | After 1200 shots |
| 600 yards / m | After 2000 shots |
Move the used X-rubber to the rear when fitting a new one at the front.
Inspecting and replacing the temperature shields
The temperature shields maintain an even temperature inside the target, including in direct sunlight. Projectiles wear the shields.
Over time, projectiles create an opening in the centre of the shields. Replace the centre section of the front shield and the rear shield when the opening reaches approximately 40 cm (15 inches) in diameter.
Sunlight and other environmental factors also degrade the temperature shields. Replace them if they no longer hold together or retain their shape.
Target inspection and maintenance
Repair ricochet damages to target rubber skin
Sideways or deformed projectiles can create large holes in the rubber skin.
If the holes are in the X-rubber, replace it to prevent scoring errors.
Holes in the main skin outside the X-rubber must be patched. Use spray adhesive and tape, or fast-curing superglue and a rubber patch.
Delete
Inspecting the target rubber skin
Replace the rubber skin in the following situations:
| 1. |
Numerous shot holes in the rubber skin can reduce measurement accuracy, particularly around the opening. Loose, coin-sized rubber pieces are a clear sign of wear.
If the edge of the opening is worn, carefully enlarge it with scissors. The rubber band must still cover the entire opening with a 3–4 cm margin. |
| 2. | The rubber skin loses tensile strength as it ages. Wind can then cause the measuring chamber between the skins to collapse inwards. As a temporary solution, the skin can be loosened, stretched and refitted. |
| 3. | Old rubber can crack. These cracks can develop into holes that prevent the measuring chamber from remaining soundproof. |
Cleaning the sensors
Rubber particles and other debris fall to the bottom of the target and can collect on the sensors.

Clean the sensors approximately every 3000 shots and before competitions. Gently remove particles from the sensor heads with a soft brush.

Open the service hatch at the bottom of the target to access the sensor array. First remove the FX target face and lower temperature shield, then release the two rubber straps holding the hatch. Remember to secure the straps again after cleaning.
Delete
Inspecting the target face
Projectiles wear the target face. Replace it when it no longer provides a clear aiming picture. Undo the retaining nuts on the front before changing the face. This does not apply to faces attached with hook-and-loop fasteners. See the parts list.
Delete
Inspecting the target service panel
The service hatch at the bottom provides access to the electronics and lower sensors. Open and close it using the white rubber straps at the bottom of the target.
Check that the hatch, hinges and straps are intact and that the hatch closes fully. There must be no cracks or gaps through which sound can enter. Keep the hatch closed and the straps secured, except during inspection or maintenance inside the target.
Delete
Inspecting and replacing the temperature shields
The temperature shields maintain an even temperature inside the target, including in direct sunlight. Projectiles wear them, particularly the centre of the rear shield.
| The rear temperature shield may start to bulge after a few hundred shots. | ![]() |
| The rear shield has a removable section to prevent the measuring chamber from collapsing. | ![]() |
| Remove this section when the shield starts to bulge. Refit the shield with the side containing the removable section facing the rubber skin. | ![]() |
Replace the rear temperature shield when the opening reaches approximately 40 cm (15 inches) in diameter.
Sunlight and other environmental factors also degrade the temperature shields. Replace them if they no longer hold together or retain their shape.
Delete
Target repairs
Repairs
The I/O cables at the bottom of the target can be replaced with the front service hatch open. Each cable has a connector at both ends: one for the rest of the eScore system and one for the target electronics.
Route the cables through the slot in the frame and form a loop immediately inside it. Secure them with tape, cable ties and cable clips. The loop must not touch the adjacent sensor.

Protecting the U4H target
Protecting the target against stray shots and ricochets
The target's critical electronic components are located at the bottom, behind the service panel. Protect this area with a protective wall or plates to reduce maintenance costs and improve durability. Target stands with protective plates are available on request.
See YouTube video for recommendations on how to install the targets.

Protection from ricochets and shrapnel
Fragments from bullet catchers can cut or short-circuit cables. Route cables between targets, antennas, batteries and other equipment carefully to minimise this risk. Cover steel bullet catchers with rubber or another suitable energy-absorbing material to reduce escaping ricochets and fragments.