Maintaining sensors on U targets

Maintaining sensors on eScore U targets

Equipment required

- Small brush

Procedure

Step 1 – Remove the target face and temperature shield

Remove the top cover

Unscrew the four front guide pin nuts

Remove the target face and temperature shield.

 

Remove

Step 2 - Open service panel

Open the service lid by releasing the two rubber straps on the front of the target service hatch. Lift the lid up to access electronics compartment.

Rubber straps keeps the service hatched closed. Right side is released

Lifting the service hatch reveals electronics and sensors. (U-target)

For H-targets the sensors are only placed in the bottom corners, not in the center.

Remove

Step 3 – Inspect the sensors

  • Inspect the sensors.
  • Lightly touch the sensors to ensure that they are correctly fastened.
  • Use a small brush to wipe away debris that may have landed on top of the sensors.


Sensor with debris

Remove

Step 4 – Close the service hatch

Close the service hatch and secure both rubber straps.

Ensure a tight seal around the hatch, both straps must be used.


Remove

Step 5 – Fit the temperature shield and target face

  • Install the temperature screen first by entering all four guide pins.
    Ensure that the rubber side of the foam faces forward.


  • Install the target face on the four alignment pins.



Remove

The target face may be orientation sensitive!

Ensure that the orientation is correct! - If center marks / engraving on the target face are visible, they shall face towards the shooter. If partnumber is engraved on the target face it shall be oriented so that the text is readable in the upright position


  • Fasten the four guide pin nuts by hand. There is no need to use excessive force while fastening these nuts.
  • Remember to re-attach the rain cover.